Customization: | Available |
---|---|
Application: | Industry |
Hardness: | Hardened |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
G3 | Model code |
F/L | Mount mode F:Flange mounted L:Foot mounted |
M/B/S | Power mode M:Standard model(motor without brake) B:Brake model (motor with brake) S:IEC input Without character means shaft input |
1:30 | Speed ratio of reducer (i=5,10,15,20~~~200) |
0.3kw | Motor power (0.1kw 0.2kw 0.4kw 0.75kw) |
22mm | Output shaft Diameter (18,22,28,32,40,50mm) |
Performance parameter | |||||||||||||||||
Normal ratio | 5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 80 | 100 | 100 | 120 | 160 | 200 | ||
0.2kw | output shaft | 18mm | 22mm | 28mm | |||||||||||||
actual speed ratio | 4.97 | 10.12 | 15.16 | 20.08 | 24.89 | 30.86 | 39.56 | 49.09 | 62.17 | 79.12 | 98.18 | 104.08 | 120.88 | 165 | 196.43 | ||
rpm | 282 | 138 | 92 | 70 | 56 | 45 | 35 | 29 | 23 | 18 | 14 | 13 | 12 | 8 | 7 | ||
NM | 50Hz | 6.5 | 12.6 | 19.1 | 26.3 | 32.6 | 38.9 | 50.4 | 63 | 75.6 | 100.8 | 103.9 | 125.4 | 150 | 200.4 | 250.7 | |
60Hz | 5.4 | 10.5 | 16.6 | 21.9 | 27.1 | 32.4 | 42 | 52.5 | 63 | 84 | 86.6 | 104.5 | 125 | 167 | 208.9 | ||
Fr1 | 588 | 882 | 980 | 1180 | 1270 | 1760 | 1860 | 1960 | 2160 | 2450 | 2450 | 2840 | 3330 | 3430 | 3430 | ||
Fr2 | 196 |
Output torque of IEC input reducer | |||||||||||||||||
Normal ratio | 5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 80 | 100 | 100 | 120 | 160 | 200 | ||
0.18kw | Output shaft | 18mm | 22mm | 28mm | |||||||||||||
NM | 50Hz | 5.9 | 11.4 | 17.2 | 23.6 | 29.3 | 35 | 45.3 | 56.7 | 68.1 | 90.7 | 93.5 | 112.8 | 135 | 180.3 | 225.6 | |
60Hz | 4.9 | 9.5 | 14.9 | 19.7 | 24.4 | 29.2 | 37.8 | 47.3 | 56.7 | 75.6 | 77.9 | 94 | 112.5 | 150.3 | 188 |
Quantity of lubricant | ||||||
output shaft dia | 18mm | 22mm | 28mm | 32mm | 40mm | 50mm |
quantity of lubricant | 140 | 200 | 400 | 600 | 900 | 1600 |
Power kw | Output shaft | Ratio | Primary outline and dimension-mount(G3LM) | |||||||||||||||||
A | D | E | F | J | G | H | K | P | S | T | U | V | W | X | Y | Y1 | ||||
1 | 2 | |||||||||||||||||||
0.2 | 18 | 5/10/15/20/25 | 267 | 270 | 40 | 110 | 135 | 16.5 | 65 | 9 | 45 | 30 | 18 | 20.5 | 129 | 183 | 6 | 133 | 85 | 10 |
22 | 30/40 50/60 80/100 | 293 | 296 | 65 | 130 | 155 | 19 | 90 | 11 | 55 | 40 | 22 | 24.5 | 129 | 193 | 6 | 139.5 | 90 | 12 | |
28 | 100/120 160/200 | 306 | 309.5 | 90 | 140 | 175 | 23.5 | 125 | 11 | 65 | 45 | 28 | 31 | 129 | 203 | 8 | 170 | 110 | 15 |
Defective reason | analysis | Solution method | |
Noise | Knocking | Gear surface damaged | Contact manufacturer,replace gear set |
Continual cacophony | Bearing damaged | Replace the damaged bearing | |
Periodical cacophony | Particle on gear surface | Check gear surface | |
Neigh | Lack of lubricant | Fill with lubricant | |
Intermittent cacophony | Dirty lubricant | Replace the new lubricant | |
Shake | Fixed foundation shake | Deflective mount on the surface | Re-adjust fixed pedestal |
Output shaft shake | Bearing damage | Replace the damaged bearing | |
Inner gear parts shake | Gear damage | Replace the damaged gear | |
Housing shake | Defective gear assembly | Re-adjust the gear set | |
Leakage | Oil seal leakage | Oil seal vulcanize | Replace the damaged oil seal |
Housing leakage | Housing with the sand hole | Replace housing with the sand hole | |
Housing shake | O-ring damaged | Replace the damaged O-ring | |
Over-heating | Oil seal damaged | Over-tighten oil seal | Replace over-tighten oil seal |
Over-heat housing | Over-road | Re-calculate load | |
Lack of lubricant | Low lubricant | Fill with lubricant | |
Over-heat motor | 1,the temperature of environment is too high 2,airiness is bad 3,pressure is too high or too low | 1,take measure to reduce the temperature 2,clean out the wind passage and check the motor if cooling fan has been damaged 3,adjust electrical source pressure | |
The motor can`t work | Electrical source haven`t been switched on | Check if the switch is contacted will,if the fuse wise is broken or the motor down-lead is broken | |
The rotate speed of the output shaft is too low |
Wrong control connection outside Over loading Wrong ratio Electrical source pressure too low Over-load |
Correct is on the right connection Reduce the load Check the rotation ratio of the cooling fan and output shaft by hand Adjust electrical source pressure Reduce load |
|
Motor circumrotate,output shaft don`t circu mrotate |
Inner gear set damaged | Please contact the manufacture to replace the gear set |